Category: Classification of electronic componentsDescription: PSENsgate Safety door monitoring system, safety protection locking device, safety interlock responder technology, 2 safety inputs used to connect multiple safety switches in series, 2 safety output locking pins can prevent bolt tongues from being accidentally opened, detect bolt tongue and lock pin damage, padlock used to restart interlock auxiliary release, used to open the safety door escape release when the factory voltage is turned off, used to quickly release from the dangerous area in emergency situations, suitable for plug-in spring-loaded terminal LEDs on the left and right hinged doors, used for: power supply voltage/fault, door closure, status of dangerous machinery, input status, bolt tongue engagement PSENsgate safety door monitoring system combines safety door monitoring, safety protection locking, and control components in one system. This non-contact switch is also equipped with additional functions such as emergency stop and escape release. Recognized EC, T Ü V standards EN 60204-1, EN 60947-5-3, EN 62061: SIL CL 3, EN ISO 13849-1: PL e and Class 4 EN 1088。 Non contact switch6545
-
Category: Safety typeDescription: SAFETY RELAY, 2NO 110VAC; Series: PNOZ X; Voltage, Coil AC Nom: 110V; Contact Configuration: DPNO; Voltage, Contact A...8242
-
Category: Safety typeDescription: SAFETY RELAY, 3NO 24VAC; Series: PNOZ X; Voltage, Coil AC Nom: 24V; Contact Configuration: 3 N/O + 1 N/C; Voltage, Co...7719
-
Category: Safety typeDescription: RELAY, SAFETY, 240VAC; Coil Voltage VAC Nom: 24V; Coil Resistance: 1.5KΩ; Contact Current Max: 6A; Contact Voltage ...28111+$1109.306610+$1070.383650+$1065.5182100+$1060.6528150+$1052.8682250+$1046.0567500+$1039.24521000+$1031.4606
-
Category: Classification of electronic componentsDescription: Self-monitored emergency stop relay Safety relays for emergency stop circuits as per the Machines directives and EN 60204 and EN 292 standards Cabling on 1 or 2 channels Display LEDs on input channels 1 and 2 Fitted with a return loop for self-monitoring of external relays or contactors Input for validation push-button. DIN rail mount Output contacts: | 3 N/O + 1 N/C ---|--- Consumption: | 2VA/2W max. Breaking capacity: | 8A/2000VA max. Release time: | 20 ms Voltage/current in the emergency stop buttons: | 24 Vdc/50mA Operating temperature: | –10°C to +55°C Supply voltage | 24Vac Stock | release ---|--- no. | voltage 178-2438 | 24 Vac ### Recognized BG EML II, T Ü V, SUVA, SA INRS, and CSA tested # # # Safety Relays5213
-
Category: Classification of electronic componentsDescription: PNOZ X3 The PNOZ X3 safety relay provides safety related interrupts for safety circuits. It complies with the requirements of EN 60947-5-1, EN 60204-1, and VDE 0113-1. ###Features and advantages: 3 safety contacts (N/O) and 1 auxiliary contact (N/C), positive guidance connection option, used for emergency stop, safety threshold switch, reset button, and light barrier status indicator. Can monitor external contactors/relays, semiconductor output display, ready for operation. Circuit redundancy, with built-in self-monitoring safety function to remain effective in case of component failure. In each on-off cycle, it automatically tests the correct opening and closing of the safety function relay. The relay has electronic fuses to monitor manual reset DIN rail installation screw terminal PLe (Class 4), complies with EN ISO 13849-1: 2006 standard Class 4, complies with EN 954-1 standard SIL CL 3, complies with EN IEC 62061 standard SIL3, complies with IEC 61511 standard. Apply PNOZ X3 safety relay for emergency stop and safety door applications. ###Recognize CE, cULus certification, T Ü V, KOSHA, CCC. ###Standards EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1, EN 60947-5-1. ###Safety relay7645
-
Category: Classification of electronic componentsDescription: PILZ PSEN CS5.1N Safety Interlock Switch, PSENcode, PSEN Series, Connector, IP66, IP6768291+$1041.421910+$1004.880850+$1000.3132100+$995.7455150+$988.4373250+$982.0426500+$975.64791000+$968.3397
-
Category: Interlocking switchDescription: PILZ 506343 Safety interlock switch, PSENmag, DPST normally open, connector, IP6768111+$734.893010+$709.107350+$705.8841100+$702.6609150+$697.5037250+$692.9912500+$688.47871000+$683.3216
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The basic device of the safety controller PNOZ m B0 is an energy-saving safety controller, which can save up to 80% energy compared to similar products. It has an illuminated display screen that provides quick debugging and diagnosis. ###Features and advantages comply with EN ISO 13849-1 PLe and IEC 62061 SIL CL 3 standards. The maximum achievable value depends on the application. PNOZmulti configurator can be used to configure replaceable program memory through chip card or USB interface. There are 20 safety inputs, up to 8 of which can be configured as auxiliary outputs and 4 safety semiconductor outputs, depending on the application. PLe, SIL CL 3 4 test pulse outputs, up to 4 of which can be configured as standard output lighting display screen for error message display of power supply voltage status, input and output, status and device information, custom text rotation knob for menu control. Application PNOZ m B0 Connect emergency stop, dual hand button, beam, scanner, start switch, safety door switch, work mode selector switch, mute, safety pad, and sensor. ###Recognize CE, cULus certification, T Ü V, BG, CCC. ###Comes with screw terminal blocks and a 32 kB chip card. ###Safety controller8492
-
Category: Relays, I/O modulesDescription: Relay, safety, 24V AC/DC, 3 normally open, 1 normally closed54791+$1955.181810+$1937.407425+$1928.520250+$1919.6330100+$1910.7459150+$1901.8587250+$1892.9715500+$1884.0843
-
Category: Classification of electronic componentsDescription: PILZ 570280 Hinges, PSEN HS166401+$432.642710+$421.356350+$412.7035100+$409.6938200+$407.4365500+$404.42681000+$402.54582000+$400.6647
-
Category: Interlocking switchDescription: PILZ 570270 Safety interlock switch, PSENhinge, DPST normally closed, connector, 230 V, 3 A, not rated50731+$1338.899110+$1326.727325+$1320.641450+$1314.5555100+$1308.4696150+$1302.3837250+$1296.2978500+$1290.2119
-
Category: Safety typeDescription: PILZ 751134 Safety Relay, 3PST-NO, 240V, 6A, PNOZ s4 Series, DIN Rail, Spring Clamp21981+$1748.406010+$1732.511425+$1724.564150+$1716.6168100+$1708.6695150+$1700.7222250+$1692.7749500+$1684.8276
-
Category: Classification of electronic componentsDescription: Connection Cable, 5M, Angled, 4P M8 Connector, Screw-On33401+$140.734710+$137.063450+$134.2487100+$133.2696200+$132.5354500+$131.55641000+$130.94452000+$130.3326
-
Category: Classification of electronic componentsDescription: Module: safety relay; Series: PNOZ e2.2p; Inputs:2; Outputs:556681+$1727.143010+$1711.441725+$1703.591150+$1695.7404100+$1687.8898150+$1680.0391250+$1672.1885500+$1664.3378
-
Category: Safety typeDescription: PILZ 750135 Safety Relay, 4PST-NO, 240V, 6A, DIN Rail, Screw91641+$3616.631710+$3583.753225+$3567.314050+$3550.8748100+$3534.4355150+$3517.9963250+$3501.5571500+$3485.1178
-
Category: Interlocking switchDescription: PILZ 540005 Safety interlock switch, PSENcode, DPST normally open, DPST normally closed, connector, not rated58151+$1531.678510+$1517.754225+$1510.792050+$1503.8298100+$1496.8676150+$1489.9055250+$1482.9433500+$1475.9811
-
Category: Interlocking switchDescription: PILZ 506340 Safety interlock switch, PSENmag, DPST normally open, connector, IP6715021+$508.758910+$495.486950+$485.3117100+$481.7725200+$479.1181500+$475.57891000+$473.36692000+$471.1549
-
Category: Classification of electronic componentsDescription: PNOZ XV3 The safety relay PNOZ XV3P 3 provides safety related interrupts for the safety circuit. It complies with the requirements of EN 60947-5-1, EN 60204-1, and VDE 0113-1. ###Features and advantages: Relay output, instantaneous 3 safety contacts (normally open), positive guidance relay output, re energization delay: 2 safety relays (normally open), positive guidance, with adjustable or fixed power-off delay (depending on the device) LED for indicating operating voltage, LED for switching all output relays and reset circuit position connections for safety limit switches, emergency stops, safety door switches, and external reset button output circuits. Redundant single or dual channel operation for monitoring external contactors/relays. Feedback control loop to prevent machine operation in case of power supply failure, component failure, relay coil defect, cable breakage, and grounding fault. DIN rail installation screw terminal block # # # Application PNOZ XV3P 3 safety relay for emergency stop and Security door application. ###Recognize CE, cULus certification, T Ü V, CCC. ###Standards EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1, EN 60947-5-1. ###Safety relay7071
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The communication/fieldbus module CANopen PNOZ m ES CANopen expansion module is connected from the PNOZmulti 2 configurable control system to the basic device. Features and advantages recognized by CE, cULus certification, T Ü V, BG, CCC. Comes with screw terminal blocks. Safety controller7959
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The multi link module PNOZ m EF can securely connect two PNOZ multi 2 basic devices. Features and advantages recognized by CE, cULus certification, T Ü V, BG, CCC. Standard EN ISO 13849-1 PLe; EN ISO 13849-1 Class 4; EN 62061 SIL CL 3; IEC 61511 SIL 3。 Comes with screw terminal blocks. Safety controller2524
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The communication/fieldbus module Powerlink PNOZ m ES Powerlink expansion module is connected from the PNOZmulti 2 configurable control system to the basic device. ###Features and advantages can be configured in the PNOZmulti configurator for Ethernet POWERLINK (Ethernet POWERLINK V2 protocol) by rotating the switch to select the workstation address: 1 The minimum cycle time for 239 32 B output and 32 B input applications is 275 μ s, and the minimum cycle time for 254 B input and 32 B output maximum PDO size is 500 μ s. 128 virtual inputs and outputs can be defined on the control system PNOZmulti of the PNOZmulti configurator for communication with the fieldbus Ethernet POWERLINK. Up to 1 PNOZ m ES Powerlink can be connected to the basic device. Transmission rate: 100 Mbps. Connected to the fieldbus through RJ45 connectors. # # # Approved CE, cULus certification, T Ü V, BG, CCC. ###Comes with screw terminal blocks. ###Safety controller1005
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The sports monitoring module PNOZ m EF * MM expansion module is connected to the basic device from the PNOZ multi 2 configurable control system. Two models are available: PNOZ m EF 1MM provides one axis safety monitoring, while PNOZ m EF 2MM provides two independent axis monitoring. Features and advantages: Application recognition of CE, cULus certification, T Ü V, BG, CCC. Standard EN ISO 13849-1 PLe; EN ISO 13849-1 Class 4; EN IEC 62061 SIL CL 3; IEC 61511 SIL 3。 Comes with screw terminal blocks. Safety controller5271
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The communication/fieldbus module Profibus PNOZ m ES Profibus expansion module connects the PNOZmulti 2 configurable control system to the basic device. Features and advantages recognized by CE, cULus certification, T Ü V, BG, CCC. Comes with screw terminal blocks. Safety controller2438
-
Category: Classification of electronic componentsDescription: PNOZmulti 2 The communication/fieldbus module EtherCAT PNOZ m ES EtherCAT expansion module is connected from the PNOZmulti 2 configurable control system to the basic device. Features and advantages recognized by CE, cULus certification, T Ü V, BG, CCC. Comes with screw terminal blocks. Safety controller9884
-
Category: Classification of electronic componentsDescription: PNOZmulti The motion monitoring module PNOZ ms2p is used to monitor stillness, speed, and rotation direction, up to EN 954-1 Class 3 standard. It can only be connected to PNOZmulti basic devices. ###Features and advantages of monitoring 2 independent coordinate axes connected to each axis: 1 incremental encoder, 2 proximity switches, 1 incremental encoder, 1 proximity switch. Monitoring static, speed (can be set to 8 values), and rotation direction can be selected in the PNOZmulti configurator. Coordinate axis type, input device type, and reset mode status indicator can be used to indicate power supply voltage, incremental encoder, proximity switch, static and overspeed status, system faults. Proximity switch connection technology (male connection terminal). Incremental encoder connection technology (RJ-45 female connector). Electrical isolation between connectors X1, X12, and X22. Up to 4 speed monitors can be connected to basic devices. # # # Approved CE, cULus certification, T Ü V, BG, KOS. SHA, CCC. ###Standard EN ISO 13849-1 PLe; EN IEC 62061 SIL CL 3。 ###Comes with screw terminal blocks. ###Safety controller5584
-
Category: Interlocking switchDescription: PILZ 570245 Safety interlock switch, PSENmech, 2NC, tightened, 240 V, 3 A, not rated9656
-
Category: Classification of electronic componentsDescription: Expander Module, PZE X4P, 24VDC, Screw Terminals26161+$1130.916510+$1091.235250+$1086.2750100+$1081.3149150+$1073.3786250+$1066.4344500+$1059.49021000+$1051.5539
-
Category: Classification of electronic componentsDescription: Module: safety relay; Series: P2HZ X1P; Inputs:2; Outputs:4; IP4080341+$3993.984510+$3957.675625+$3939.521150+$3921.3666100+$3903.2121150+$3885.0577250+$3866.9032500+$3848.7487